The 9293510721 from EBM-Papst is a compact axial fan with a wall ring from the S-Panther series, designed for 24 V DC with a wide voltage range of 12–28 V. The fan measures 119×119×32 mm and delivers a maximum airflow of 187 m³/h – a strong choice for demanding cooling needs in confined spaces.
The fan is excellent for industrial electronics cooling, server cabinets, and automation where reliable DC cooling with speed monitoring is required. The brushless DC motor and ball bearings ensure long operating life and low maintenance.
- Airflow: 187 m³/h (max free flow)
- Maximum static pressure: 66 Pa
- Speed: 2,700 rpm
- Voltage: 24 V DC (range 12–28 V)
- Power: 3.4 W | Rated current: 140 mA
- Noise level: 43 dB(A)
- Ball bearings for long service life
- Tachometer signal (open collector) for speed monitoring
Reserv stocks genuine EBM-Papst parts and delivers quickly for those who can't wait. You can trust that you will receive the correct component – every time. See the datasheet on the product page for complete technical information.
Technical specifications
| Product attribute | Value |
|---|---|
| Airflow at 0 Pa | 187 m³/h |
| Speed | 2700 rpm |
| Power | 3.4 W |
| Voltage | 24V DC VAC |
| Motor frame | The casing is made of plastic and has dimensions of 119×119×32 mm with a mass of 0.23 kg. The mounting screws are ISO 4762 M4 (degreased, without spacers or additional supports). Mounting can be done in any position with regard to the axis direction. The airflow is directed outwards over the supports. |
| Casing | plastic, square |
| Impeller | The fan impeller is made of plastic and mounted on an axial fan measuring 119×119×32 mm. At a nominal speed of 2700 rpm, the fan provides a maximum free air flow of 187 m³/h and a maximum static pressure of 66 Pa. The optimal operating point is 138 m³/h at 22 Pa. |
| Bearing type | ball bearing |
| Motor code | 4314 N/2N |
| Rotation direction | clockwise |
| Motor type | The motor is a brushless DC motor designed for 24 V nominal voltage with a voltage range of 12–28 V. It has automatic restart protection in the event of a locked rotor and is equipped with a rectifier diode for reverse polarity protection. The motor has an integrated open-collector (2N) tachometer signal for speed monitoring. The protection class is III. |